Lennox, Air Conditioner, T CLASS, 4 Ton, 14 SEER, 1 Stage, 460 VAC 3 Ph 60 Hz, TSA048H4N42G

Cat # : 33W71

Model/Part # : TSA048H4N42G

Quantity:

Save to List


Brand
Lennox
Catalog Number
33W71
Model/Part Number
TSA048H4N42G
Minimum Order Quantity
0.0
Base Unit of Measure
Unit(S)
Family
TSA
Series
T CLASS
Type
Commercial Air Conditioner
Nominal Cooling Capacity
4 Ton
Product Voltage
460 VAC 3 Ph 60 Hz
Product Depth
28.25 Inch
Product Width
28.25 Inch
Product Height
37.25 Inch
Compressor Type
1-Stage
Gross Weight
221 lbs.
SEER IEER EER
14 SEER
Energy Star Certified
No
Refrigerant Type
R-410A

Product Overview

TSA048H4

T-Class™ Air Conditioners (TSA) and Heat Pumps (TPA)

High Efficiency 3-5 Ton Units

True performance backed by rugged durability

Efficiency

  • Up to 16.2 SEER and 9.7 HSPF
  • Scroll compressor provides smooth, efficient and quiet operation
  • High-efficiency outdoor coil provides exceptional heat transfer and low air resistance for high-efficiency operation
  • Precision-balanced, direct-drive fan is designed to run slower for an enhanced level of quiet operation
  • ENERGY STAR® qualified
Comfort/IAQ
  • Humiditrol® dehumidification system reduces moisture and controls the spread of airborne contaminants
Serviceability
  • Brass service valves isolate the refrigeration system in outdoor units and allow for simple access
  • Refrigerant line connections and electrical inlets are located in one central area of cabinet for easy access
Reliability
  • Heavy-duty fan guard increases safety
  • Corrosion-resistant cabinet is galvanized steel under a two-layer painted surface that protects against rust and corrosion
  • Drainage holes prevent damaging moisture from collecting inside the base pan
  • Enhanced coil guard protects the condenser coil, maintaining the efficiency of the unit
  • Fan motor features a fully enclosed design with a rain shield to provide maximum protection from weather, dust, corrosion and moisture
  • Crankcase heater protects the compressor against refrigerant migration that can occur during low ambient operations
  • Solid-state defrost control monitors the condition of the coil and quickly and efficiently clears the buildup of frost on the coil (heat pump only)
Options
  • Compressor low ambient cutoff
  • Compressor time-off control
  • Loss-of-charge kit
  • High-pressure switch kit
  • Hail guards
  • Freezestat
  • Mounting base
  • Unit stand-off kit
  • Refrigerant line kits
  • Low ambient kit to 30°F
  • Mild weather kits
  • Compressor sound cover
  • Time-delay relay kit